Madrid, Spain

CONDITION OF BARAJAS AIRPORT CAR PARK (T4) AFTER A TERRORIST ATTACK

Client

AENA

Year

2008

Key facts

Module D of the T4 car park. Car park 960 x 80 m2 on 4 levels above ground

Services

Inspection. Inspection and tests to define areas to be rebuilt and areas to be repaired. Non-destructive testing and sampling for laboratory tests. Calculation checks. Report on the outcomes with recommendations on the actions to be taken.